Catalogue
English

2MS - Engine S for rail systems

 

2MS - Engine S for rail systems Weight - from 42 kg depending on the model Standard equipments 1 - Electric brake2 - Unlocking lever for emergency manual activation 2MST - Winding drum made of aluminium for the winding of the cable with its blocking2MSTR - Roll device for the containment of the cable
View all
2MST - Drum made of aluminum for the winding of the cable with its blocking Standard models - 2MST - 15 - central opening - max. stroke < 15 m (7,5 + 7,5 m + overlap)side opening - max. stroke < 8 m 2MST - 20 - central opening - max. stroke < 20 m (10 + 10 m + overlap)side opening - max. stroke < 10,5 m 2MST - 25 - central opening - max. stroke < 25 m (12,5 + 12,5 m + overlap)side opening - max. stroke < 13 m 2MST - 30 - central opening - max. stroke < 30 m (15 + 15 m + overlap)side opening - max. stroke < 15,5 m
2MSTR - Roll device for the containment of the cables
2QE - Panel board for 2MS - Engine S for rail systems Standard models with fixed speed 50 cm / second 2QE - T400F_R04 - 3Φ - 400V-50Hz - for engine 2MS - T400_037 2QE - T400F_R08 - 3Φ - 400V-50Hz - for engine 2MS - T400_075 2QE - T400F_R11 - 3Φ - 400V-50Hz - for engine 2MS - T400_110 2QE - S230F_R04 - 1Φ - 230V-50Hz - for engine 2MS - S230_037 Standard equipments 1 - on / off switch2 - warning light for electric tension presence3 - warning light for thermal intervention4 - safety key for the locking of the board5 - emergency stop button6 - safety key to disable the use of the controls7 / 8 / 9 - open / stop / close buttons I - input for electricity supply of the electric boardO1 - output for the electricity supply of the engine + 15 m cableO2 - output for limit switches + 15 m cable A - electronic control unit for phases to prevent the reversal of the engineB - thermal magnetic circuit breaker for overload cut-out of the engineC - configuration for insertion of external control device for control room
2QE - Panel board for 2MS - Engine S for rail systems Standard models with variable speed from 0 to 100 cm / second 2QE - T400V_R04 - 3Φ - 400V-50Hz - for engine 2MS - T400_037 2QE - T400V_R08 - 3Φ - 400V-50Hz - for engine 2MS - T400_075 2QE - T400V_R11 - 3Φ - 400V-50Hz - for engine 2MS - T400_110 2QE - S230V_R04 - 1Φ - 230V-50Hz - for engine 2MS - S230_037 Standard equipments 1 - on / off switch2 - warning light for electric tension presence3 - speed variator4 - safety key for the locking of the board5 - emergency stop button6 - safety key to disable the use of the controls7 / 9 - open / close buttons8 - stop button + warning light for thermal intervention I - input for electricity supply of the electric boardO1 - output for the electricity supply of the engine + 15 m cableO2 - output for limit switches + 15 m cableO3 - output for insertion of external control device for control room A - potentiometerB - thermal magnetic circuit breaker for overload cut-out of the engine
2QE - Panel board per 2MS - Engine S for rail systems Optional equipments 2RC - Remote control C 2RCT - Transmitter Open / Stop / Close 2RCR - External receiver
2QE - Panel board for 2MS - Engine S for rail systems Optional equipments - 2QER - Push-button panel for control room- 2QEP - Hanging push-button panel- 2QEX - DMX512 controller with input/output 3P XLR connectors
2MS - Engine S for rail systems Weight - from 42 kg depending on the model Standard equipments 1 - Electric brake2 - Unlocking lever for emergency manual activation 2MST - Winding drum made of aluminium for the winding of the cable with its blocking2MSTR - Roll device for the containment of the cable
For rail systems

Standard models
power supply ...!..... rail .....!. curtain kg .!. opening .!. maximum stroke
2MS - T400_037
3Φ - 400V-50Hz .!.. straight ..!.. < . 90 kg .!.. central ..!. < 15 m (7,5+7,5 m)
3Φ - 400V-50Hz .!.. straight ..!.. < . 90 kg .!.... side ....!. < . 8 m
2MS - T400_075
3Φ - 400V-50Hz .!.. straight ..!.. < 150 kg .!.. central ..!. < 25 m (12,5+12,5 m)
3Φ - 400V-50Hz .!.. straight ..!.. < 150 kg .!.... side ....!. < 13 m
3Φ - 400V-50Hz .!.. curved ...!.. < 100 kg .!.. central ..!. < 20 m (10+10 m)
3Φ - 400V-50Hz .!.. curved ...!.. < 100 kg .!.... side ....!. < 10,5 m
2MS - T400_110
3Φ - 400V-50Hz .!.. straight ..!.. > 150 kg .!.. central ..!. > 25 m (12,5+12,5 m)
3Φ - 400V-50Hz .!.. straight ..!.. > 150 kg .!.... side ....!. > 13 m
3Φ - 400V-50Hz .!.. curved ...!.. < 150 kg .!.. central ..!. < 25 m (12,5+12,5 m)
3Φ - 400V-50Hz .!.. curved ...!.. < 150 kg .!.... side ....!. < 13 m
2MS - S230_037
1Φ - 230V-50Hz .!.. straight ..!.. < . 80 kg ..!.. central ..!. < 15 m (7,5+7,5 m)
1Φ - 230V-50Hz .!.. straight ..!.. < . 80 kg ..!.... side ....!. < . 8 m

Standard equipments
of the engine
- electric brake
- emergency manual operation
- aluminium drum for winding of the cable with its blocking
- roll device for the containment of the cables
Standard equipments
of the panel board
- fixed speed 50 cm / second
- safety key for the locking of the board
- safety key to disable the use of the controls
- low voltage controls
- input for electricity supply of the electric board
- output for the electricity supply of the engine + 15 m cable
- output for limit switches + 15 m cable
- electronic control unit for phases to prevent the reversal of the engine
- thermal magnetic circuit breaker for overload cut-out of the engine
- configuration for insertion of external control device for control room

Optional equipments
of the panel board
- variable speed from 0 to 100 cm / second
- 2QER - Push-button panel for control room
- 2RC - Remote control C
- 2QEP - Hanging push-button panel
- 2QEX - DMX512 controller with input/output 3P XLR connectors

Warning:
the images on this page are indicative, the illustrated products are subject to change without notice.

See also ...

Casino de la Vallée

Curtains for multi-purpose settings

Congress hall

Curtains for multi-purpose settings

Hall for shows

Curtains for multi-purpose settings

Sala Tripcovich

Curtains for multi-purpose settings

Stage for open-air theatre

Curtains for multi-purpose settings

Studio Foce

Curtains for multi-purpose settings

Teatro Amilcare Ponchielli

Curtains for historical theaters

Teatro Grande

Curtains for historical theaters

Teatro Lirico, ''Chérubin''

Curtains for shows

Teatro Massimo

Curtains for historical theaters

Teatro Rossini

Curtains for historical theaters

Teatro Vittorio Alfieri

Curtains for historical theaters

Theatre art deco

Public places